Menü überspringen

LIC 4117, LIC 4197

Linear scale

LIC 4007

Measuring standard

Coefficient of linear expansion

Steel scale tape with METALLUR absolute and incremental track

αtherm 10 · 10-6 K-1

Accuracy grade*

± 3 µm (up to ML 1 040 mm), ± 5 µm (as of ML 1 240), ± 15 µm1)

Measuring length ML* in mm

240, 440, 640, 840, 1040, 1240, 1440, 1640, 1840, 2040, 2240, 2440, 2640, 2840

3040, 3240, 3440, 3640, 3840, 4040, 4240, 4440, 4640, 4840, 5040, 5240, 5440, 5640

5840, 6040

Weight Scale tape

Parts kit

Scale-tape carrier

31 g/m

20 g

68 g/m

Scanning head

AK LIC 411

AK LIC 419 F

AK LIC 419 M

AK LIC 419 P

Interface

EnDat 2.2

Fanuc Serial Interface

Þi interface

Mitsubishi high speed interface

Panasonic Serial Interface

Ordering designation*

EnDat22

Fanuc05

Mit03-4

Mit02-2

Pana01

Resolution*

0.01 µm (10 nm)

0.005 µm (5 nm)

0.001 μm (1 nm)

0.01 µm (10 nm)

0.005 µm (5 nm)

0.001 µm (1 nm)3)

0.01 µm (10 nm)

0.005 µm (5 nm)

0.001 μm (1 nm)

Calculation time tcal

Clock frequency

≤ 5 µs

16 MHz

Traversing speed2)

≤ 600 m/min

Electrical connection*

Cable, 1 m or 3 m with 8-pin M12 coupling (male) or 15-pin D-sub connector (male)

Cable length
(with HEIDENHAIN cable)

≤ 100 m

≤ 50 m

≤ 30 m

≤ 50 m

Voltage supply

3.6 V to 14 V DC

Power consumption2) (max.)

At 3.6 V: ≤ 800 mW

At 14 V: ≤ 900 mW

At 3.6 V: ≤ 950 mW

At 14 V: ≤ 1 050 mW

Current consumption (typical)

At 5 V: 75 mA (without load)

At 5 V: 95 mA (without load)

Vibration 55 Hz to 2 000 Hz

Shock 6 ms

≤ 500 m/s2 (EN 60 068-2-6)

≤ 1 000 m/s2 (EN 60 068-2-27)

Operating temperature

-10 °C to 70 °C

Weight Scanning head

Connecting cable

Connector

≤ 18 g (without connecting cable)

20 g/m

M12 coupling: 15 g; D-sub connector: 32 g

* Please select when ordering

1) ± 5 µm after linear length-error compensation in the subsequent electronics

2) See General electrical information in the Interfaces of HEIDENHAIN Encoders brochure

3) Up to measuring length ML ≤ 4 140